banner
Home > Blog

Maintenance and repair methods using gasoline generators(c)

Post Time: 2016-08-17

Third, clean fuel filter through the fuel filter to remove dust and moisture in the fuel.
(A) Remove the filter cup, water and dust away.
(B) the use of gasoline to clean the filter and filter cup.
(C) of the cup tightly screwed on the body, will not confirm the leak fuel.
Fourth, check the carbon brush: If the brush is extremely wear it and the rotor slip ring contact pressure will change, so that the slip ring surface is not flat, as well as the performance of the generator will be uneven. To check the performance of the brush when the generator every 500 hours or uneven. As the length of the brush at 5 mm or less, it is necessary, and new replacement.
(A) Remove the end cap and brush cover.
(B) Disconnect the cables, remove the brush.
(C) When installing a new brush, pay full attention to the relative position of the slip ring to match the direction of the brush.

Online Service